Bull NovaScale 3005 Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Serveurs Bull NovaScale 3005 Series. BSM 1.0 Remote Hardware Management CLI Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - & ESCALA

BSM 1.0 Remote Hardware Management CLI Reference Manual NOVASCALE & ESCALA REFERENCE 86 A2 58FA 01

Page 2

viii BSM 1.0 - Remote Hardware Management CLI Reference Manual

Page 3 - BSM 1.0

Chapter 1. Hardware Management Commands 1 Chapter 1. Hardware Management Commands Description The Hardware Management CLI provides an easy Command

Page 4

2 BSM 1.0 - Remote Hardware Management CLI Reference Manual Note The following Hardware Management commands (NovaScale 5005 & 6000 series only

Page 5 - Table of Contents

Chapter 1. Hardware Management Commands 3 bsmpower bsmpower.sh is used to power ON/OFF a server, a Blade server, an Escala PL server, or to activat

Page 6

4 BSM 1.0 - Remote Hardware Management CLI Reference Manual -h Displays command usage. -l level Specifies the severity of the messages to be logge

Page 7

Chapter 1. Hardware Management Commands 5 -T timeout SNMP timeout (default value is 20s). SSH connection timeout (default value is 30s). -o outf

Page 8

6 BSM 1.0 - Remote Hardware Management CLI Reference Manual Return Codes: 0 command accepted. -1 command failed. Note A power ON command on an

Page 9 - Introduction

Chapter 1. Hardware Management Commands 7 Return Codes for NovaScale 5005 and 6000 Servers 0 Server ON or RUNNING. 1 Server OFF. 2 Server in a TR

Page 10

8 BSM 1.0 - Remote Hardware Management CLI Reference Manual $ bsmpower.sh -a status -m fame -D FAME000 -M paptest2 -u pap -p pap POWERING ON FAILED

Page 11 - Description

Chapter 1. Hardware Management Commands 9 bsmreset bsmreset.sh is used to forcibly Power Reset a server. Usage NovaScale 5005 and 6000 series serve

Page 13

10 BSM 1.0 - Remote Hardware Management CLI Reference Manual -o outfile Output file name to which stdout and stderr outputs are redirected. Note

Page 14

Chapter 1. Hardware Management Commands 11 bsminfo bsminfo.sh is used to direct, to the standard output, the configuration information specified in

Page 15

12 BSM 1.0 - Remote Hardware Management CLI Reference Manual NovaScale servers using the ipmilan model bsminfo.sh [-h] -i information -m ipmilan -H

Page 16

Chapter 1. Hardware Management Commands 13 bsminfo Options and Parameters -i Option PAM Level (no -D or -e option) Domain Level (-D option spec

Page 17 - POWERING ON

14 BSM 1.0 - Remote Hardware Management CLI Reference Manual -i Option Hardware Component Level (-e option specified) hardwarestatus Returns the p

Page 18

Chapter 1. Hardware Management Commands 15 Output: PAM:/DOMAINGROUP_<cellsblock name>/DOMAIN_<domain name>/ CellBlockIdent=[0-15] … Ex

Page 19

16 BSM 1.0 - Remote Hardware Management CLI Reference Manual bsminfo -i domainhardware domainhardware is used to display the list and the functional

Page 20 - Return Codes

Chapter 1. Hardware Management Commands 17 bsminfo -i domainlogistics domainlogisitics is used to list the functional status of all common logistic

Page 21

18 BSM 1.0 - Remote Hardware Management CLI Reference Manual Presence Status Functional Status Failure Status Fault Status Exclusion Status Power S

Page 22

Chapter 1. Hardware Management Commands 19 bsminfo -i FRUtemperatures FRUtemperatures is used to display all the specified hardware object temperat

Page 23

NOVASCALE & ESCALA BSM 1.0 Remote Hardware Management CLI Reference Manual Software January 2009 BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 AN

Page 24

20 BSM 1.0 - Remote Hardware Management CLI Reference Manual FRU Info Memory Size Firmware Version DPS x MIDPLANE x IOB x FPB x

Page 25

Chapter 1. Hardware Management Commands 21 PAM:/CELLSBLOCK_CHARLY3/MODULE_0/PMB/RunningMaestroVersion=21.11.2.1_DEBUG_MEM / 3.8.0.2 PAM:/CELLSBLOCK

Page 26

22 BSM 1.0 - Remote Hardware Management CLI Reference Manual bsminfo -i domaininfo domaininfo is used to display domain memory size and BIOS version

Page 27 - -u pap -p pap

Chapter 1. Hardware Management Commands 23 Example: $ bsminfo.sh -i domainexclusion -m fame -D FAME000 -M paptest2 -u pap -p pap PAM:/DOMAINGROUP_P

Page 28

24 BSM 1.0 - Remote Hardware Management CLI Reference Manual PAM:/module/?? CompanyName : Rainbow Technologies PAM:/module/?? ProductName : Sentinel

Page 29

Chapter 1. Hardware Management Commands 25 PAM:/CELLSBLOCK_FAME000/MODULE_0/QBB_0/FRU=Board CustomField : SPS(6.0/01;5.4/01) PAM:/CELLSBLOCK_FAME00

Page 30

26 BSM 1.0 - Remote Hardware Management CLI Reference Manual bsminfo -i BMCinfo BMCinfo is used to display BMC information such as IPMI version, fir

Page 31

Chapter 1. Hardware Management Commands 27 bsmlog bsmlog is used to direct system log contents (SEL) to the standard output. bsmlog is also used to

Page 32

28 BSM 1.0 - Remote Hardware Management CLI Reference Manual -h Displays command usage. -l level Specifies the severity of the messages to be logg

Page 33

Chapter 1. Hardware Management Commands 29 -T timeout SNMP timeout: default value is 20. SSH connection timeout (default value is 120s). -o

Page 34

The following copyright notice protects this book under Copyright laws which prohibit such actions as, but not limited to, copying, distributing, mo

Page 35

30 BSM 1.0 - Remote Hardware Management CLI Reference Manual Notes • For Blade servers, the <event target> field is replaced by two field

Page 36 - Example:

Chapter 1. Hardware Management Commands 31 $ bsmlog.sh -n 5 -m fame -M papcharly3 -u pap -p pap 638 | 2b2b2215 | 09/27/04 | 16:44:31 | /DOMAINGROUP

Page 37

32 BSM 1.0 - Remote Hardware Management CLI Reference Manual Rank : 8 Index : 13 Local Time : 09/27/07 11:18:30 Severity

Page 38

Chapter 1. Hardware Management Commands 33 $ bsmlog.sh -m HMC -M 129.183.12.80 –I id_dsa –C config_bsm -u hscroot –d /etc/ssh –t console –n 3 -v

Page 39

34 BSM 1.0 - Remote Hardware Management CLI Reference Manual bsmfru bsmfru displays the FRU contents on the standard output. For NovaScale 5005 &

Page 40 - Examples

Chapter 1. Hardware Management Commands 35 1 : only the FAILED completion of the command is logged. 3 : FAILED and successful completion of t

Page 41

36 BSM 1.0 - Remote Hardware Management CLI Reference Manual • For Blade servers, if no “–B bladename” option is specified, all the FRUs of all the

Page 42

Chapter 1. Hardware Management Commands 37 FRU Device Description: module 1 MFL Chassis ChassisType : Other Chassis PartNumber : Chassis SerialN

Page 43

38 BSM 1.0 - Remote Hardware Management CLI Reference Manual bsmsensor bsmsensor is used to direct sensor values to the standard output. This comman

Page 44

Chapter 1. Hardware Management Commands 39 -p password User password. (Authentication key for Express5800 servers). -c For sensors of the blade c

Page 45

Preface iii Table of Contents Introduction...

Page 46

40 BSM 1.0 - Remote Hardware Management CLI Reference Manual Output <sensor addr> | <sensor id> | <sensor value> | <sensor unit

Page 47

Chapter 1. Hardware Management Commands 41 $ bsmsensor.sh -m ipmilan -H nsmaster -u MWA -p guest -t ”Power Supply” 0x00200010 | Power Supply 1 |

Page 48

42 BSM 1.0 - Remote Hardware Management CLI Reference Manual bsmsnmp bsmsnmp is used to add or remove a server from the list of SNMP trap receivers.

Page 49

Chapter 1. Hardware Management Commands 43 Return Codes 0 command accepted. -1 command failed. -2 command for creation of a subscription already e

Page 50

44 BSM 1.0 - Remote Hardware Management CLI Reference Manual Examples: $ bsmsnmp.sh -a delete_dest -m pam -M paptest2 -u pap -p pap -d frcls1234 -P

Page 51

Chapter 1. Hardware Management Commands 45 trap_disable trap_disable is used to disable the <prefix>_SNMP_<destination> subscription, a

Page 52

46 BSM 1.0 - Remote Hardware Management CLI Reference Manual bsmpowergroup The bsmpowergroup command is used to execute a power action (on/off/off_f

Page 53

Chapter 1. Hardware Management Commands 47 -w offdelay Specifies the time (in seconds) for a domain to reach the INACTIVE status after powering it

Page 54

48 BSM 1.0 - Remote Hardware Management CLI Reference Manual Examples $ bsmpowergroup.sh -a status -m pam -M paptest2 -g all -u pap -p pap domain FA

Page 55

Chapter 1. Hardware Management Commands 49 bsmsol The bsmsol command is used to establish a Serial-Over-Lan session. This command is available onl

Page 56

iv BSM 1.0 - Remote Hardware Management CLI Reference Manual bsminfo -i identitycard...

Page 57

50 BSM 1.0 - Remote Hardware Management CLI Reference Manual bsmidentify The bsmidentify command is used to identify physically a remote host via us

Page 58

Chapter 1. Hardware Management Commands 51 bsmHWinfocmd bsmHWinfocmd is used to get various IPMI information such as BMC parameters, LAN configurat

Page 59

52 BSM 1.0 - Remote Hardware Management CLI Reference Manual Return Codes 0 command accepted. -1 command failed. bmc_info bmc_info is used to get

Page 60

Chapter 1. Hardware Management Commands 53 user_list user_list is used to get information about the users configured for the LAN channel used to ac

Page 61

54 BSM 1.0 - Remote Hardware Management CLI Reference Manual Number of Retries : 3 Alert Gateway : Default Alert IP Address

Page 62

Chapter 1. Hardware Management Commands 55 PEF table entry : 2 Status : inactive PEF table entry : 3 Statu

Page 63

56 BSM 1.0 - Remote Hardware Management CLI Reference Manual bsmFWupg bsmFWupg is used to upgrade, using an external tool, the firmware of Remote Ma

Page 64

Chapter 1. Hardware Management Commands 57 Example $ bsmFWupg.sh -t kiratool –H 129.182.6.110 –u super -p pass –F “fw-wub-MESCB_010100_0026.bin” S

Page 65

58 BSM 1.0 - Remote Hardware Management CLI Reference Manual

Page 66 - Requirement

Appendix A: Server ON / OFF Status Codes 59 Appendix A: Server ON / OFF Status Codes This appendix lists the interconnection between the ON / RUNN

Page 67 - Example

Preface v Examples ...

Page 68

60 BSM 1.0 - Remote Hardware Management CLI Reference Manual

Page 69

Appendix B: User/Password Internal Authentication File 61 Appendix B: User/Password Internal Authentication File User/Password Authentication Most

Page 70

62 BSM 1.0 - Remote Hardware Management CLI Reference Manual bsmcfg_auth_cmd command Usage bsmcfg_auth_cmd.sh [-h] [-a action] [-M manager] [-H mana

Page 71 - User/Password Authentication

Appendix B: User/Password Internal Authentication File 63 Examples: $ bsmcfg_auth_cmd.sh -a add -u pap -p pappwd -M paptest2 Key entry successfully

Page 72

64 BSM 1.0 - Remote Hardware Management CLI Reference Manual $ bsmcfg_auth_cmd.sh -a getE -u ftpuser -S MyFtpServer zzzzzz $ bsmcfg_auth_cmd.sh -a g

Page 73

Appendix B: User/Password Internal Authentication File 65 $ bsmcfg_auth_cmd.sh -a getD -u MWA2 -H “*” mwa2pwd del This action is used to delete, in

Page 74

66 BSM 1.0 - Remote Hardware Management CLI Reference Manual list This action is used to display the contents of the internal authentication file, t

Page 75

Index 67 Index A authentication file, 61 B bmc_info, 52 BMCinfo, 26 bsmcfg_auth_cmd, 62 bsmfru, 34 bsmFWupg, 56 bsmHWinfocmd, 51 bsmidentity, 50 b

Page 76

68 BSM 1.0 - Remote Hardware Management CLI Reference Manual T tiger model, 2 trap_disable, 45 trap_enable, 44 trap_status, 45 U User/Password, 61 u

Page 78

vi BSM 1.0 - Remote Hardware Management CLI Reference Manual

Page 79

BULL CEDOC 357 AVENUE PATTON B.P.20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A2 58FA 01

Page 80 - REFERENCE

Preface vii Introduction Scope and Audience of this Manual The purpose of this manual is to describe the Hardware Management CLI (Command Line Inte

Commentaires sur ces manuels

Pas de commentaire